Trouble
Cause
Remedy
Battery polarity
re-
versed.
Battery consumes
ex-
cessive
water.
Connected backwards
on airplane
or charger.
Charging rate too high
(if in all cells).
Battery should be slowly
discharged
completely
and then charged cor-
rectly and tested.
Correct
charging rate.
Cracked jar
(one cell
Replace battery.
only).
BATTERY-DISCONNECT
SOLENOID
Does not operate.
Open circuit.
Repair wiring.
Dirty contacts on con-
nector plug.
Open-circuited
solenoid
coil.
Plunger binding.
Clean contacts.
Replace unit.
Remove and wash plung-
er and housing thor-
oughly with carbon tet-
rachloride.
Change
spring compression
only as a last resort.
Intermittent
operation.
Short-circuited
coil.
Loose electrical
con-
nection.
Replace coil.
Clean and
tighten electrical
con-
nections.
Plunger binding.
See remedy pertainingto
"Plunger binding" under
"Does not operate."