Inspection Of Keyless Start Control Module And Its Circuits - Suzuki GRAND VITARA JB416 Service Manual

Hide thumbs Also See for GRAND VITARA JB416:
Table of Contents

Advertisement

10E-6 Keyless Start System:

Inspection of Keyless Start Control Module and Its Circuits

Keyless start control module and its circuits can be checked at keyless start control module wiring couplers by
measuring voltage and resistance.
CAUTION
!
Keyless start control module cannot be checked by itself. It is strictly prohibited to connect voltmeter
or ohmmeter to keyless start control module with coupler disconnected from it.
Voltage Check
1) Disconnect negative cable (–) at battery.
2) Remove keyless start control module from vehicle body referring to "Keyless Start Control Module Removal and
Installation: in related manual".
3) Connect connector to keyless start control module.
4) Check voltage at each terminal number of couplers connected.
NOTE
• As each terminal voltage is affected by the battery voltage, confirm that it is 11 V or more when
ignition switch is ON.
• Voltage with asterisk (*) cannot be measured by voltmeter because it is pulse signal.
[A]: Keyless start control module connector (viewed from harness side)
[A]
20
19
18
16
15
14
37
36
34 33 32
G44
11
10
9
8
7
6
5
4
3
2
30 29
24 23
1
S5JB0EA504013