Suzuki GRAND VITARA JB416 Service Manual page 73

Hide thumbs Also See for GRAND VITARA JB416:
Table of Contents

Advertisement

Terminal
Wire
No.
color
E23-40
E23-41
E23-42
E23-43
E23-44
E23-45
Radiator cooling
RED/
E23-46
fan relay No.1
BLK
output
Radiator cooling
E23-47
RED
fan relay No.2
output
Radiator cooling
RED/
E23-48
fan relay No.3
YEL
output
A/C compressor
E23-49
PNK
relay output (if
equipped with A/C)
Circuit
Normal voltage
10 – 14 V
0 – 2 V
10 – 14 V
0 – 2 V
10 – 14 V
0 – 2 V
10 – 14 V
0 – 1 V
Engine General Information and Diagnosis:
Condition
Ignition switch turned ON,
engine coolant temp.:
below 95 °C (203 °F), or
A/C refrigerant pressure:
below 300 kPa (43.5 psi)
with A/C switch turned on
while engine is running.
Ignition switch turned ON,
engine coolant temp.: 97.5
°C (207.5 °F) or higher, or
A/C refrigerant pressure:
340 kPa (49.3 psi) or
higher with A/C switch
turned on while engine is
running.
Ignition switch turned ON,
engine coolant temp.:
below 100 °C (212 °F), or
A/C refrigerant pressure:
below 1300 kPa (188.5
psi) with A/C switch turned
on while engine is running.
Ignition switch turned ON,
engine coolant temp.:
102.5 °C (216.5 °F) or
higher, or A/C refrigerant
pressure: 1600 kPa (232
psi) or higher with A/C
switch turned on while
engine is running.
Ignition switch turned ON,
engine coolant temp.:
below 100 °C (212 °F), or
A/C refrigerant pressure:
below 1300 kPa (188.5
psi) with A/C switch turned
on while engine is running.
Ignition switch turned ON,
engine coolant temp.:
102.5 °C (216.5 °F) or
higher, or A/C refrigerant
pressure: 1600 kPa (232
psi) or higher with A/C
switch turned on while
engine is running.
Engine running, A/C
switch OFF and blower
selector at OFF position.
Engine running, A/C
switch ON and blower
selector at 1st position or
more.
1A-55
Remarks

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grand vitara jb420