150 •
I/O Modules
Design of the Process Data for PROFIBUS-DP

5.2.28 PROFIsafe I/O Modules

750-660, 750-665, 750-666
Process Image Length in [Byte]
Register communication possible
Yes (not possible)
No
Mapping
Data format
I/O area
Channel 1
MOTOROLA / INTEL
Input
D0
STATUS (PROFIsafe)
Consecutive number F-Module
CRC F-Module High Byte
CRC F-Module Low Byte
Input
Output
-
5
Output
D0
CONTROL (PROFIsafe)
Consecutive number F-Host
CRC F-Host High Byte
CRC F-Host Low Byte
WAGO-I/O-SYSTEM 750
-