Programmable Field Bus Controller 750-833
Description
• The diagnostics concept is based on the identification and channel based
diagnostics in accordance with EN 50170. In this manner it is not necessary to
program modules for evaluation of the manufacturer specific diagnostics
information.
• Process data length
max. 244 byte input process image (128 byte up to SW 02)
max. 244 byte output process image (128 byte up to SW 02)
• Automatic recognition of the transmission speed on the PROFIBUS of
9.6 kBd to 12 MBd
• All I/O modules from the WAGO-I/O-SYSTEM 750 are supported
• Configuration modules can be parameterized as wildcards.
• Parameterizable substitute value for each channel
• D-Sub 9 pole bus connection