WARNING!
DISCONNECT BATTERY BEFORE SERVICING.
1
Turn the key switch OFF and disconnect the battery.
2
Open the Side Access Door to access the Circuit Breaker Panel Assembly.
3
Mount the Time Delay (A) as shown with the (B) Screw and (C) Nut from the kit.
4
Directly above this location, hanging from the wiring harness are the wires needed to connect the Time Delay (A).
5
There is a tab connector with two Black wires connected to it and another with two Orange wires. A third with a Red/Blk wire and a fourth with a
Red/Brn wire. These last two will have a jumper wire between them, remove and discard this jumper wire.
6
Connect these wires to the Time Delay according to Figure 2.
7
Close Access Door and re-connect the battery.
8
Test the Time Delay for proper operation, the Shaker should remain
ON for 15 seconds after releasing the Shaker Switch.
FIGURE 2
TOP
BLK
RED/BRN
© 1999 Nilfisk-Advance, Inc. Printed in USA
56418834 SHAKER TIMER KIT
For Advance 2060 / Nilfisk SR 1800
CONTENTS OF KIT
ITEM
PART NO.
56040694
A
56491870
B
56002824
C
56002768
INSTALLATION INSTRUCTIONS
ORN
RED/BLK
QTY
DESCRIPTION
1
Instruction Sheet
1
Time Delay
1
Scr, Pan Phil 10-24 x 1.25
1
Nut, Hex Nyl Loc 10-24
C
FIGURE 1
FRONT
4/99 Form No. 56040694
B
A