SWEEPING SYSTEM
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
SIDE BROOM SWITCH (S14) ADJUSTMENT
1
Remove four bolts on right side hopper panel, remove two screws holding latch in place. Remove the side panel.
2
Loosen the two bolts holding switch bracket in place.
3
Disconnect the two-wire connector on switch and insert continuity tester.
4
Adjust switch for no continuity when broom lever is in raised position and continuity when lever is in lowered position.
5
Tighten two bolts on switch bracket and reconnect two-wire connector. Check for proper operation.
6
Reinstall side panel and latch.
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

SIDE BROOM MOTOR REMOVAL

1
See Figure 6. Remove side broom Thumbnut
(FF) and remove side broom from motor.
2
Remove the drive pin holding Hub (GG) on
motor shaft and remove drive hub.
3
Loosen the side broom adjustment Handle (HH)
and let side broom motor down to the lowest
position.
4
Remove and plug the two hydraulic hoses.
Note: Mark hoses for correct rotation when
reinstalling.
5
Remove two 1/2-13 Nuts (II) and Bolts (JJ), lift
and remove motor from bracket weldment (KK).
6
Reassemble in reverse order and check side
broom adjustment. (See side broom mainte-
nance section)
7
Test for proper operation and check for leaks.
18 - FORM NO. 56043051 / Retriever
FRONT
2060
FIGURE 6
HH
KK
II
JJ
GG
FF