Debris Hopper System; Functional Overview; Electrical Diagram - Nilfisk-Advance Advance Retriever 2060 Service Manual

Table of Contents

Advertisement

HOPPER SYSTEM
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

FUNCTIONAL OVERVIEW

Hopper System
A hopper mounted on the front of the machine is used to collect debris. A litter door is located on the front of the hopper to allow the
operator to throw large debris that cannot be swept into the hopper. The hopper broom opening has a dump door that is open when
sweeping and closed when raising the hopper. A hydraulic cylinder is used to open and close the dump door. A larger cylinder is used
to raise and lower the hopper. The back gear pump of the auxiliary pump runs the two cylinders. The hydraulic oil flows through the
priority divider to a directional control valve. The directional control valve has two switches built into it, the hopper switch (S15) and the
dump door switch (S16). When the dump door lever is moved to either the open or closed position, (S16) will energize the directional
by-pass solenoid (L1) and allow oil flow to the directional control valve. When the hopper lever is moved to the up position (S15) will
energize (L1) and oil will flow to the directional control valve. If the hopper lever is moved to the down position the interlock relay (K3)
will be energized and open the circuit to (S16) and not allow the dump door to be moved. The hopper/dump door interlock switch (S12)
will open when the dump door is closed or the hopper is up, de-energizing the door indicator light relay (K6) and opening the circuit to
the broom switches. The relief valve for the hopper hydraulic system is located in the directional control valve and is set to open at 2400
PSI.
+
12V
.08 AMP
3.8 AMPS
ORN
Hopper / Dump Door Interlock Switch
.16 AMPS
ORN
ORN
K3
1.17 AMPS
ORN
Hopper System Electrical Diagram
24 - FORM NO. 56043051 / Retriever
H21
VIO
Hopper Door Lamp
S12
WHT/BLU
S15
1
2
3
4
Hopper Valve Switch
S16
VIO/WHT
1
2
VIO/WHT
3
4
Dump Valve Switch
2060
GRA/YEL
DOWN
GRN/GRA
BLU/YEL
UP
OPEN
BLU/YEL
BLU/YEL
CLOSE
12V
K6
BLK
Hopper Door Relay
BLK
K6
Hopper Door Relay
BLK
K3
Interlock Relay
Directional Control Valve
Bypass Solenoid
BLK
L1
_

Advertisement

Table of Contents
loading

Table of Contents