On-Site Installation Requirements - Daikin Altherma 3 GEO Series Installer's Reference Manual

Hide thumbs Also See for Altherma 3 GEO Series:
Table of Contents

Advertisement

9.1.3 On-site installation requirements

EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12
Smart Grid application
Item
LAN adapter software
Unit control method
Domestic hot water
settings
Power consumption
control settings
INFORMATION
For instructions on how to perform a software update, see
4
software" [
 113].
What you need on site to install the LAN adapter depends on the system layout.
BRP069A61
Smartphone with the Daikin Residential Controller app
IF connection to an
electricity meter (X2A)
IF connection to a solar
inverter/energy
management system
(X1A)
It is recommended to ALWAYS keep the LAN adapter
software up-to-date.
On the user interface, make sure to set [2.9]=2
(Control = Room thermostat)
To allow for energy buffering in the domestic hot
water tank, on the user interface, make sure to set
[9.2.1]=4 (Domestic hot water = Integrated).
On the user interface, make sure to set:
[9.9.1]=1 (Power
Continuous)
[9.9.2]=1 (Type = kW)
Always
PC/laptop with Ethernet connector
Router (DHCP enabled)
Depending on the system layout
Electricity meter
2‑wire cable
2‑wire cable
Circuit breaker
(100 mA~6 A, type B)
9
LAN adapter
|
Requirement
consumption
control =
"9.4.4  Updating
BRP069A62
Installer reference guide
103

Advertisement

Table of Contents
loading

Table of Contents