Daikin Altherma 3 GEO Series Installer's Reference Manual page 190

Hide thumbs Also See for Altherma 3 GEO Series:
Table of Contents

Advertisement

10
|
Configuration
Power consumption control
Installer reference guide
190
[D‑00]
0
2
Power consumption control
See
"5  Application guidelines" 
functionality.
#
[9.9.1]
[4-08]
Continuous power consumption control and power consumption control with
digital inputs
The type of limit needs to be set in combination with the continuous power
consumption control and the power consumption control with digital inputs.
#
[9.9.2]
[4-09]
Limit when [9.9.1]=Continuous and [9.9.2]=Amp:
#
[9.9.3]
[5-05]
Limits when [9.9.1]=Inputs and [9.9.2]=Amp:
#
[9.9.4]
[5-05]
[9.9.5]
[5-06]
[9.9.6]
[5-07]
[9.9.7]
[5-08]
Limit when [9.9.1]=Continuous and [9.9.2]=kW:
Backup heater
Forced OFF
Allowed
4
[
  24] for detailed information about this
Code
Power consumption control:
0 No: Disabled.
1 Continuous: Enabled: You can set one
power limitation value (in A or kW) to which
the system power consumption will be
limited for all the time.
2 Inputs: Enabled: You can set up to four
different power limitation values (in A or kW)
to which the system power consumption will
be limited when the corresponding digital
input asks.
3 Current sensor: Enabled: You can set a
current limitation value (in A) to which the
household current will be limited.
Code
Type:
0 Amp: The limitation values are set in A.
1 kW: The limitation values are set in kW.
Code
Limit: Only applicable in case of full time
current limitation mode.
0 A~50 A
Code
Limit 1: 0 A~50 A
Limit 2: 0 A~50 A
Limit 3: 0 A~50 A
Limit 4: 0 A~50 A
Compressor
Forced OFF
Description
Description
Description
Description
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12