Router - Daikin Altherma 3 GEO Series Installer's Reference Manual

Hide thumbs Also See for Altherma 3 GEO Series:
Table of Contents

Advertisement

9
|
LAN adapter

9.2.2 Router

To connect the router
Installer reference guide
106
Connectors
1
2
a1
3
4
N
a2
L
b
1
2
c
d
a1 To solar inverter/energy management system
a2 230 V AC detection voltage
b To electricity meter
c Factory-mounted cable to indoor unit (P1/P2)
d To router (via the factory-mounted Ethernet cable outside of the unit)
Connections
Field-supplied cables:
Connection
Router (via the
factory-mounted
Ethernet cable
outside of the unit,
which is coming
from X4A)
Electricity meter
(X2A)
Solar inverter/
energy
management
system + 230 V AC
detection voltage
(X1A)
(a) Ethernet cable: Respect the maximum allowed distance between LAN adapter and
router, which is 50 m in case of Cat5e cables, and 100 m in case of Cat6 cables.
(b) These wires MUST be sheathed. Recommended strip length: 6 mm.
(c) All wiring to X1A MUST be H05VV. Required strip length: 7 mm. For more
information, see
Make sure the LAN adapter can be connected via a LAN connection.
The minimum category for the Ethernet cable is Cat5e.
Use one of the following ways (A, B or C) to connect the router:
X1A
X2A
X3A
X4A
Cable section
2
0.75~1.25 mm
2
0.75~1.5 mm
Depends on
application
"9.2.4 Solar inverter/energy management
Wires
Maximum cable
length
50/100 m
(b)
2
100 m
100 m
(c)
system" [
4
 109].
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12
(a)