9.1.1 System layout

EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12
LED
LD4
Indication of Smart Grid
activity.
INFORMATION
The DIP switch is used to configure the system. For more information, see
"9.4 Configuration – LAN
When the LAN adapter performs a Smart Grid compatibility check, LD4 flashes.
This is NOT erroneous behaviour. After a successful check, LD4 will either stay ON
or go OFF. When it keeps flashing for more than 30 minutes, the compatibility
check failed, and NO Smart Grid operation is possible.
Integrating the LAN adapter into the heat pump system allows for the following
applications:
App control (only)
Smart Grid application (only)
App control + Smart Grid application
App control (only)
a1
X4A
A See "9.2.2 Router" [
a1 Factory-mounted Ethernet cable
a2 Router
a3 Smartphone with app control
Description
4
adapter" [
 112].
A
a3
a2
4
 106].
9
LAN adapter
|
Behaviour
LED ON: system running in
the
"Recommended
"Forced ON", or "Forced OFF"
Smart Grid operation mode.
LED OFF: system running in
the
"Normal
operation"
Smart Grid operation mode,
or
operating
in
operation conditions (space
heating/cooling,
production
of domestic hot water).
LED flashing: LAN adapter
performing a Smart Grid
compatibility check.
Installer reference guide
ON",
normal
101