Space heating/cooling control........20 Latest revisions of the supplied documentation may be available on 6.2.5 Domestic hot water control ......... 21 the regional Daikin website or via your dealer. 6.2.6 Contact/helpdesk number ........... 21 Weather-dependent curve............21 The original documentation is written in English. All other languages 6.3.1...
▪ A subset of the latest technical data is available on the regional Use the handles at the back and at the bottom to carry the unit. Daikin website (publicly accessible). ▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required). Online tools...
WARNING Make sure installation, servicing, maintenance and repair comply with instructions from Daikin and with applicable legislation (for example national gas regulation) and are executed only by authorised persons. 2 Remove the upper front panel. Open the hinges at the top and NOTICE slide the top panel upwards.
Prerequisite: The upper front panel and front panel have been removed. 1 Remove the fixing plate at the top of the unit. 2 Tilt the switch box to the front and lift it out of its hinges. 2× Installation manual EHFH03S18DJ3V Daikin Altherma 3 R F 4P596803-1 – 2019.10...
There are no requirements for the minimum water volume. However, if you converted the unit to a heating/cooling unit, you need to add an additional 5 liter of water. EHFH03S18DJ3V Installation manual Daikin Altherma 3 R F 4P596803-1 – 2019.10...
These shut-off valves are field supplied. 4 Check for water leaks. 5 Manually operate the field-installed pressure relief valve to ensure a free water flow through the discharge pipe. Installation manual EHFH03S18DJ3V Daikin Altherma 3 R F 4P596803-1 – 2019.10...
"5.3.2 To connect the backup heater supply" [ 4 11]. heater) power User interface "5.3.3 To connect the user interface" [ 4 12]. Shut-off valve "5.3.4 To connect the shut-off valve (Heating/Cooling)" [ 4 13]. EHFH03S18DJ3V Installation manual Daikin Altherma 3 R F 4P596803-1 – 2019.10...
Maximum running current: 6.3 A LAN adapter – System requirements Preferential kWh Wires: 2×(0.75~1.25 mm²) rate power supply The requirements posed on the Daikin Altherma system depend on Maximum length: 50 m. contact the LAN adapter application/system layout (app control): Preferential kWh rate power supply...
OR a safety thermostat. 1N~, 50 Hz 5.3.2 To connect the backup heater power 230 V AC supply Backup heater Power supply Wires type 1N~ 230 V (6V) 2+GND EHFH03S18DJ3V Installation manual Daikin Altherma 3 R F 4P596803-1 – 2019.10...
Secure the wiring to the front part of the casing using the wiring retainer and clamp. 6 Reinstall the faceplate onto the wallplate. Be careful NOT to pinch the wiring when attaching the frontplate to the unit. Installation manual EHFH03S18DJ3V Daikin Altherma 3 R F 4P596803-1 – 2019.10...
3 Fix the cable with cable ties to the cable tie mountings. [7.3] Set schedules > [7.3.7] DHW pump unit" [ 4 5]): 1 Open the following (see "3.2.1 To open the indoor EHFH03S18DJ3V Installation manual Daikin Altherma 3 R F 4P596803-1 – 2019.10...
Wire between X2M and A4P Wires connected to the alarm output A4P Installation of EKRP1HBAA is required. Wire between X2M and A4P A4P Installation of EKRP1HBAA is required. Installation manual EHFH03S18DJ3V Daikin Altherma 3 R F 4P596803-1 – 2019.10...
2 Connect the power consumption digital inputs cable to the appropriate terminals as shown in the illustration below. 2 Connect the changeover to external heat source cable to the appropriate terminals as shown in the illustration below. EHFH03S18DJ3V Installation manual Daikin Altherma 3 R F 4P596803-1 – 2019.10...
After connecting the electrical wiring to the indoor unit To prevent water ingress to the switch box, seal the low voltage wiring intake using the sealing tape (delivered as accessory). Installation manual EHFH03S18DJ3V Daikin Altherma 3 R F 4P596803-1 – 2019.10...
[1-01]) by using the button. settings" [ 4 23] ▪ "6.4 Menu structure: Overview installer 6.1.1 To change the user permission level Default user permission level The default user permission level is End user. EHFH03S18DJ3V Installation manual Daikin Altherma 3 R F 4P596803-1 – 2019.10...
Number of water temperature zones: ▪ 0 (1 LWT zone): Main Cold water Shower ▪ 1 (2 LWT zones): Main + additional Domestic hot water pump Recirculation connection … disinfection Installation manual EHFH03S18DJ3V Daikin Altherma 3 R F 4P596803-1 – 2019.10...
Code Description [A.3.1.3.1] [9-09] Delta T for heating Range: 3°C~10°C [A.3.1.3.2] [9-0A] Delta T for cooling Range: 3°C~10°C Installation manual EHFH03S18DJ3V Daikin Altherma 3 R F 4P596803-1 – 2019.10...
▪ Main zone - Cooling Emitter type [A.3.1.1.7] [2-0C] ▪ Additional zone - Heating ▪ 0: Underfloor heat ▪ Additional zone - Cooling ▪ 1: Fancoil unit ▪ Tank ▪ 2: Radiator EHFH03S18DJ3V Installation manual Daikin Altherma 3 R F 4P596803-1 – 2019.10...
To fine-tune the weather-dependent curve The following table describes how to fine-tune the weather- dependent curve of a zone or tank: Installation manual EHFH03S18DJ3V Daikin Altherma 3 R F 4P596803-1 – 2019.10...
Solar kit settings are shown but are NOT applicable for this unit. Settings shall NOT be used or changed. INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. EHFH03S18DJ3V Installation manual Daikin Altherma 3 R F 4P596803-1 – 2019.10...
The refrigerant pipes (gas and liquid) are thermally insulated. 3 Select Start air purge and press The correct pipe size is installed and the pipes are 4 Select OK and press properly insulated. Installation manual EHFH03S18DJ3V Daikin Altherma 3 R F 4P596803-1 – 2019.10...
▪ Explain the user about energy saving tips as described in the ▪ 3-way valve test operation manual. ▪ Bivalent signal test ▪ Alarm output test ▪ H/C signal (heating/cooling signal) test ▪ Quick heatup test ▪ DHW pump test EHFH03S18DJ3V Installation manual Daikin Altherma 3 R F 4P596803-1 – 2019.10...
9 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). Piping diagram: Indoor unit...
X*, X*A, X*H* X*Y Connector Legend Terminal strip Main PCB * On/OFF thermostat (PC=power circuit) * Optional * Heat pump convector # Field supply * Digital I/O PCB * Demand PCB EHFH03S18DJ3V Installation manual Daikin Altherma 3 R F 4P596803-1 – 2019.10...
Page 28
Electrical meters Electrical meters thermostat thermostat For safety thermostat For safety thermostat Only for wireless On/OFF Only for wireless On/OFF Inrush Inrush current thermostat thermostat Max. load Maximum load Installation manual EHFH03S18DJ3V Daikin Altherma 3 R F 4P596803-1 – 2019.10...
Page 29
A14P: P1-P2 user interface X5M: 11-12 communication 2 core 2x0.75 A13P: P1-P2 LAN adapter communication Only for EKRUDAL1 2 core (remote user interface) 2x0.75 A10P: P1-P2 user interface communication 4D125237 EHFH03S18DJ3V Installation manual Daikin Altherma 3 R F 4P596803-1 – 2019.10...
Page 32
4P596803-1 0000000T 4P596803-1 2019.10 Verantwortung für Energie und Umwelt...