System Requirements; On-Site Installation Requirements - Daikin Altherma 3 WS EWSAH06UD 9W Series Installer's Reference Manual

Hide thumbs Also See for Altherma 3 WS EWSAH06UD 9W Series:
Table of Contents

Advertisement

10.1.2 System requirements

10.1.3 On-site installation requirements

EWSAH/X06UD
Daikin Altherma 3 WS
4P675765-1 – 2022.04
b2 Solar inverter/energy management system
b3 Solar panels
C See
"10.2.3 Electricity
c1 Electricity meter
c2 Electrical grid
The requirements posed on the heat pump system depend on the LAN adapter
application/system layout.
App control
Item
LAN adapter software
Unit control method
Smart Grid application
Item
LAN adapter software
Unit control method
Domestic hot water
settings
Power consumption
control settings
INFORMATION
For instructions on how to perform a software update, see
4
software" [
 123].
What you need on site to install the LAN adapter depends on the system layout.
BRP069A61
IF connection to an
electricity meter (X2A)
4
meter" [
 117]
It is recommended to ALWAYS keep the LAN adapter
software up-to-date.
On the user interface, make sure to set [2.9]=2
(Control = Room thermostat)
It is recommended to ALWAYS keep the LAN adapter
software up-to-date.
On the user interface, make sure to set [2.9]=2
(Control = Room thermostat)
To allow for energy buffering in the domestic hot
water tank, on the user interface, make sure to set
[9.2.1]=4 (Domestic hot water = Integrated).
On the user interface, make sure to set:
[9.9.1]=1 (Power
Continuous)
[9.9.2]=1 (Type = kW)
Always
PC/laptop with Ethernet connector
Router (DHCP enabled)
Smartphone with the ONECTA app
Depending on the system layout
Electricity meter
2‑wire cable
10
LAN adapter
|
Requirement
Requirement
consumption
control =
"10.4.4  Updating
BRP069A62