▪ Safety instructions that you must read before installing 5.15.4 Electricity meter ............26 5.15.5 Solar inverter/energy management system ....27 ▪ Format: Paper (in the box of the unit) 6 Configuration Overview: Configuration ............28 Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
Shut-off valve with integrated filter Daikin website (publicly accessible). Safety valve (connection parts for mounting on top of brine ▪ The full set of latest technical data is available on the Daikin level vessel included) Brine level vessel Business Portal (authentication required).
Tundish 15 mm inlet, 22 mm outlet WARNING Make sure installation, servicing, maintenance and repair Wall mounting set for expansion vessel comply with instructions from Daikin and with applicable legislation (for example national gas regulation) and are Instruction sheet executed only by authorised persons.
NOTICE If you remove the user interface panel, also disconnect the cables from the back of the user interface panel to prevent damage. EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
Route the wires through the 2 Front panel grommets of the upper hydro module cover. 2 Remove the insulation from the shut-off valves by cutting the X803YA cable ties. X1YA X11YB X22Y Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
When closing the indoor unit cover, make sure that the tightening torque does NOT exceed 4.1 N•m. NOTICE Make sure not to damage any insulation during the removal process. EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
To connect the brine piping NOTICE Do NOT use excessive force when connecting the field piping and make sure the piping is aligned properly. Deformation of the piping can cause malfunctioning of the unit. Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
5 Remove the safety valve on top of the vessel. 6 Top up the vessel with brine until it is approximately 2/3 filled. 7 Reconnect the safety valve. 8 Open the shut-off valve below the vessel. EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
MUST be installed on the entering piping before the water pump within 10 m of the unit. 2 Mount the expansion vessel to the wall. NOTICE Install air purge valves at all local high points. Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
Fixed grating Trapped gully Metal discharge pipe from safety device to tundish Discharge pipe from tundish, with continuous fall. See Building Regulation G3 section 3.56, Table 03 and worked example. EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
The piping in the complete water circuit MUST be insulated to prevent reduction of the heating capacity. Consider that the space heating piping can condensate during cooling operation. Foresee adequate insulation for these pipes. Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
▪ [3.9] (read-only) Control power supply) (connection to factory-mounted cable outside of the unit) C1: Power supply for the backup heater, and the rest of the unit (1N~ or 3N~) EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
Page 16
(1N~) C4: Connection of X11Y C5: Preferential kWh rate power supply for the compressor (1N~) unit" [ 4 7]. "3.2.1 To open the indoor Types of preferential kWh rate power supply: Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
Page 17
Preferential kWh rate power supply contact: 16 V DC detection (voltage supplied by PCB). The voltage-free contact shall ensure the minimum applicable load of 15 V DC, 10 mA. Connect the preferential kWh rate power supply contact (S1S) as follows. 1× EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
230 V AC supplied by PCB [2.D] Shut off valve unit" [ 4 7]): 1 Open the following (see "3.2.1 To open the indoor 1 Top panel 2 User interface panel 3 Installer switch box cover Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
X5M/6 and X5M/4; the negative polarity to X5M/5 and X5M/3. unit" [ 4 7]): 1 Open the following (see "3.2.1 To open the indoor 1 Top panel 2 User interface panel 3 Installer switch box cover EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
Wire between the installer 3 Fix the cable with cable ties to the cable tie mountings. 14a 21 switch box and main switch Installation of EKRP1HBAA is required. Cable sleeve (field supply) Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
14a 21 switch box and main switch Installation of EKRP1HBAA is required. Cable sleeve (field supply) 3 Fix the cable with cable ties to the cable tie mountings. 1× 2× 1× EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
Installation of EKRP1AHTA is required. Installation of EKRP1HBAA is required. 3 Fix the cable with cable ties to the cable tie mountings. 3 Fix the cable with cable ties to the cable tie mountings. Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
The preferential kWh rate power supply contact is connected to the same terminals (X5M/9+10) as the safety thermostat. Thus, system have EITHER preferential kWh rate power supply OR a safety thermostat. EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
(space heating/cooling, production of domestic hot water), or running in "Normal operation"/"Free running" Smart Grid operation mode. 1× 3 Fix the cable with cable ties to the cable tie mountings. Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
To router (via the factory-mounted Ethernet cable outside of the unit) d Field-supplied Ethernet cable: ▪ Minimum category: Cat5e ▪ Maximum length: ▪ 50 m in case of Cat5e cables ▪ 100 m in case of Cat6 cables EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
Make sure to connect the electricity meter in the correct Suggested electricity meters direction, so that it measures the total energy injected Phase ABB reference INTO the grid. 2CMA100152R1000 B21 212-100 2CMA100166R1000 B23 212-100 Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
"Recommended ON" operation mode. more information, see the installer reference guide. WARNING Make sure X1A/N+L are protected by a fast acting circuit breaker (rated current 100 mA~6 A, type B). EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
1 Set the user permission level to Installer. See "To — level" [ 4 28]. change the user permission 2 Go to [9.I]: Installer settings > Overview field settings. Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
Automatic (setting 1), the room frost protection function, the underfloor heating screed dryout function, and the water pipe antifreeze function will remain active even if the user does NOT confirm emergency operation. EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
Heating up or cooling down the main zone can take longer. This depends on: ▪ The water volume of the system ▪ The heater emitter type of the main zone Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
During according to a schedule. weather dependent operation, the user can shift the water temperature up or down by a maximum of 10°C. See the operation manual for more details. EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
Go to the next temperature. the curve can be adjusted by an installer or user. Confirm changes and proceed. Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
[9.B] Sensors External sensor Ext. amb. sensor offset Averaging time [9.C] Bivalent Bivalent Boiler efficiency Temperature Hysteresis INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
The fuses or locally installed protection devices are installed according to this document, and have NOT been bypassed. The power supply voltage matches the voltage on the identification label of the unit. Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
▪ Backup heater phase 2 test (3 kW capacity, only available the required capacity. when current sensors are used) ▪ Backup heater phase 3 test (3 kW capacity, only available when current sensors are used) ▪ Brine pump test EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
▪ ON: The unit operates as normal, except that the brine pump operates continuously for 10 days, independent of compressor status. ▪ OFF: Brine pump operation is linked to compressor status. Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
See "3.3.2 To connect the drain hose to drain" [ 4 10]. Fluid pressure Check whether the fluid pressure is above 1 bar. If it is lower, add fluid. EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
Page 40
Water filter Clean and rinse the water filter. NOTICE Handle the filter with care. To prevent damage to the mesh of the filter, do NOT use excessive force when you reinsert Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
4 Reinstall the clip to fix the domestic hot water OUT pipe. See also 4 Tightening torques for installation: 2 3.2.1 To open the indoor unit [} 7] Item Tightening torque Tube connection 30 N•m Temperature and pressure relief valve 40 N•m EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
10 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). 10.1 Piping diagram: Indoor unit...
Only for preferential kWh rate Backup heater control PCB power supply with separate power supply with separate Inverter PCB normal kWh rate power supply normal kWh rate power supply * Demand PCB EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
Page 44
Safety thermostat contact: DC detection (voltage supplied 16 V DC detection (voltage by PCB) supplied by PCB) Shut-off valve Shut-off valve Switch box (7) Option PCBs (7) Option PCBs Alarm output Alarm output Installation manual EGSAH/X06+10UDA9W Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
Page 45
Power limitation demand input 3 FIELD SUPPLY A8P: X801M: 3-5 signal 2 core Power limitation demand input 4 Router for LAN adapter A8P: X801M: 4-5 A15P: X4A signal ethernet 4D121919 EGSAH/X06+10UDA9W Installation manual Daikin Altherma 3 GEO 4P598591-1A – 2019.12...
WARNING TO INSTALLER ■ This installation is subject to building regulation approval, notify Local Authority of intention to install. ■ Use only manufacturer's recommended spare parts. Contact your local Daikin dealer. ■ Installed by name address tel. No.