Application guidelines
5.5 Setting up the energy metering
5.5.1 Produced heat
5.5.2 Consumed energy
Installer reference guide
42
Configuration
The indoor unit can control DHW pump operation. For more information, see
4
"10 Configuration" [
128].
▪
Via the user interface, you can read out the following energy data:
-
Produced heat
-
Consumed energy
▪
You can read out the energy data:
-
For space heating
-
For space cooling
-
For domestic hot water production
▪
You can read out the energy data:
-
Per month
-
Per year
INFORMATION
The calculated produced heat and consumed energy are an estimation, the accuracy
cannot be guaranteed.
INFORMATION
The sensors used to calculate the produced heat are calibrated automatically.
▪
The produced heat is calculated internally based on:
-
The leaving and entering water temperature
-
The flow rate
▪
Setup and configuration: No additional equipment needed.
You can use the following methods to determine the consumed energy:
▪
Calculating
▪
Measuring
INFORMATION
You cannot combine calculating the consumed energy (example: for the backup
heater) and measuring the consumed energy (example: for the rest of the unit). If
you do so, the energy data will be invalid.
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO