Daikin Altherma 3 GEO Series Installer's Reference Manual page 28

Hide thumbs Also See for Altherma 3 GEO Series:
Table of Contents

Advertisement

5
|
Application guidelines
Combination: Underfloor heating + Heat pump convectors
Installer reference guide
28
Setting
External room thermostat for the main
zone:
#: [2.A]
Code: [C-05]
Benefits
Cooling. The heat pump convector offers, besides heating capacity, also excellent
cooling capacity.
Efficiency. Optimal energy efficiency because of the interlink function.
Stylish.
Space heating is provided by:
-
The underfloor heating
-
The heat pump convectors
Space cooling is provided by the heat  pump convectors only. The underfloor
heating is shut off by the shut-off valve.
Setup
B
M1
a
A Main leaving water temperature zone
B One single room
a Remote controller of the heat pump convectors
b Remote outdoor sensor
For more information about connecting the electrical wiring to the unit, see
"8.2  Overview
of
4
actuators" [
 80].
The heat pump convectors are directly connected to the indoor unit.
A shut-off valve (field supply) is installed before the underfloor heating to
prevent condensation on the floor during cooling operation.
The desired room temperature is set via the remote controller of the heat pump
convectors.
The space heating/cooling demand signal is sent to one digital input on the
indoor unit (X2M/35 and X2M/30).
1 (1 contact): When the used
external room thermostat or heat pump
convector can only send a thermo ON/
OFF condition. No separation between
heating or cooling demand.
A
electrical
connections
Value
b
for
external
and
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12