Daikin Altherma 3 GEO Series Installer's Reference Manual page 245

Hide thumbs Also See for Altherma 3 GEO Series:
Table of Contents

Advertisement

8/11
Field settings table
Breadcrumb Field code
Setting name
9.I
[2-0C]
What emitter type is connected to the main LWT zone?
9.I
[2-0D]
What emitter type is connected to the additional LWT zone?
9.I
[2-0E]
What is the maximum allowed current over the heatpump ?
9.I
[3-00]
Is auto restart of the unit allowed?
9.I
[3-01]
--
9.I
[3-02]
--
9.I
[3-03]
--
9.I
[3-04]
--
9.I
[3-05]
--
9.I
[3-06]
What is the maximum desired room temperature in heating?
9.I
[3-07]
What is the mimimum desired room temperature in heating?
9.I
[3-08]
What is the maximum desired room temperature in cooling?
9.I
[3-09]
What is the minimum desired room temperature in cooling?
9.I
[4-00]
What is the BUH operation mode?
9.I
[4-01]
Which electric heater has priority?
9.I
[4-02]
Below which outdoor temperature is heating allowed?
9.I
[4-03]
--
9.I
[4-04]
Water pipe freeze prevention
9.I
[4-05]
--
9.I
[4-06]
Emergency setting
9.I
[4-07]
Maximum BUH capacity
9.I
[4-08]
Which power limitation mode is required on the system?
9.I
[4-09]
Which power limitation type is required?
9.I
[4-0A]
--
9.I
[4-0B]
Automatic cooling/heating changeover hysteresis.
9.I
[4-0D]
Automatic cooling/heating changeover offset.
9.I
[4-0E]
Current sensor offset
9.I
[5-00]
Is backup heater operation allowed above equilibrium temperature during space
heating operation?
9.I
[5-01]
What is the equilibrium temperature for the building?
9.I
[5-02]
Space heating priority.
9.I
[5-03]
Space heating priority temperature.
9.I
[5-04]
--
9.I
[5-05]
What is the requested limit for DI1?
9.I
[5-06]
What is the requested limit for DI2?
9.I
[5-07]
What is the requested limit for DI3?
9.I
[5-08]
What is the requested limit for DI4?
9.I
[5-09]
What is the requested limit for DI1?
9.I
[5-0A]
What is the requested limit for DI2?
9.I
[5-0B]
What is the requested limit for DI3?
9.I
[5-0C]
What is the requested limit for DI4?
9.I
[5-0D]
Backup heater voltage
9.I
[5-0E]
--
9.I
[6-00]
The temperature difference determining the heat pump ON temperature.
9.I
[6-01]
The temperature difference determining the heat pump OFF temperature.
9.I
[6-02]
--
9.I
[6-03]
--
9.I
[6-04]
--
9.I
[6-05]
--
9.I
[6-06]
--
9.I
[6-07]
--
9.I
[6-08]
What is the hysteresis to be used in reheat mode?
9.I
[6-09]
--
9.I
[6-0A]
What is the desired comfort storage temperature?
9.I
[6-0B]
What is the desired eco storage temperature?
4P569818-1A - 2019.10
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/O
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
(#) Setting is not applicable for this unit.
Range, step
Default value
0: Underfloor heating
1: Fancoil unit
2: Radiator
0: Underfloor heating
1: Fancoil unit
2: Radiator
20~50 A, step: 1 A
50 A
0: No
1: Yes
0
1
4
2
1
18~30°C, step: 0,5°C
30°C
12~18°C, step: 0,5°C
12°C
25~35°C, step: 0,5°C
35°C
15~25°C, step: 0,5°C
15°C
0: Disabled
1: Enabled
2: Only DHW
0: None
1: BSH
2: BUH
14~35°C, step: 1°C
16°C
3
0: Intermittent
1: continuous
2: Disabled
0
0: Manual
1: Automatic (normal SH/ DHW ON)
2: Auto red SH/ DHW ON
3: Auto red SH/ DHW OFF
4: Auto normal SH/ DHW OFF
[5-0D]=2: 0~9 kW, step: 1 kW
9 kW
[5-0D]≠2: 0~6 kW, step: 1 kW
6 kW
0: No limitation
1: Continuous
2: Digital inputs
3: Current sensors
0: Current
1: Power
1
1~10°C, step: 0,5°C
1°C
1~10°C, step: 0,5°C
3°C
-6~6 A, step: 0,5 A
0 A
0: Allowed
1: Not allowed
-15~35°C, step: 1°C
0°C
0: Disabled
1: Enabled
-15~35°C, step: 1°C
0°C
10
0~50 A, step: 1 A
16 A
0~50 A, step: 1 A
16 A
0~50 A, step: 1 A
16 A
0~50 A, step: 1 A
16 A
0~20 kW, step: 0,5 kW
5 kW
0~20 kW, step: 0,5 kW
5 kW
0~20 kW, step: 0,5 kW
5 kW
0~20 kW, step: 0,5 kW
5 kW
0: 230V, 1~
2: 400V, 3~
1
2~20°C, step: 1°C
6°C
0~10°C, step: 1°C
2°C
0
3
6
0
0
0
2~20°C, step: 1°C
10°C
0
30~[6-0E]°C, step: 1°C
60°C
30~min(50, [6-0E])°C, step: 1°C
45°C
Installer setting at variance with
default value