Removing An Expansion Enclosure From A System-Board Tray - IBM x iDataPlex dx340 Series Problem Determination And Service Manual

Hide thumbs Also See for x iDataPlex dx340 Series:
Table of Contents

Advertisement

Removing an expansion enclosure from a system-board tray

To remove an expansion enclosure from a system-board tray, complete the
following steps.
1. Read the safety information that begins on page vii and "Installation guidelines"
2. If the system-board tray is installed in a chassis, remove it (see "Removing the
3. Carefully set the system-board tray on a flat, static-protective surface.
4. Pull the release latch on each side of the expansion enclosure outward; then,
5. Make a note of where the cables are attached; then, if necessary, disconnect
6. Lift the expansion enclosure from the system-board tray and set the expansion
Expansion
enclosure
on page 71.
system-board tray from a 2U chassis" on page 75 or "Removing the
system-board tray from a 3U chassis" on page 77).
rotate the expansion enclosure approximately 30 degrees to a partially open
position.
them.
enclosure on a flat, static-protective surface.
Release
latch
System-board
tray
Chapter 4. Removing and replacing server components