IBM x iDataPlex dx340 Series Problem Determination And Service Manual page 60

Hide thumbs Also See for x iDataPlex dx340 Series:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 3, "Parts listing," on page 59 to determine which components are customer replaceable units (CRU) and
which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained
service technician.
Message
number
Component
202-801-xxx
Memory
44
System x iDataPlex dx340 Types 6385, 6386, 6389, 7831, 7832, and 7834: Problem Determination and Service Guide
Test
State
Memory Stress Test
Aborted
Description
Action
Internal program
1. Turn off and restart the system-board
error.
tray.
2. Make sure that the DSA code is at the
latest level. For the latest level of DSA
code, go to http://www.ibm.com/support/
docview.wss?uid=psg1SERV-DSA.
3. Make sure that the BIOS code is at the
latest level. The installed firmware level
is shown in the DSA event log in the
Firmware/VPD section for this
component. For the latest level of
firmware, go to http://www.ibm.com/
support/docview.wss?uid=psg1
MIGR-4JTS2T and select your system
to display a matrix of available
firmware.
4. Run the test again.
5. Turn off and restart the system-board
tray if necessary to recover from a
hung state.
6. Run the memory diagnostics to identify
the specific failing DIMM.
7. If the problem remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, see http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
CALL.

Advertisement

Table of Contents
loading