v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing," on page 59 to determine which components are customer replaceable units
(CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Beep code
2-1-2-3
2-2-3-1
14
System x iDataPlex dx340 Types 6385, 6386, 6389, 7831, 7832, and 7834: Problem Determination and Service Guide
Description
Check ROM copyright notice
Test for unexpected interrupts
Action
1. Reseat the chassis.
2. (Trained service technician only) Replace
the system-board tray.
1. Reseat the following components:
a. DIMM
b. System-board tray
2. Replace the following components one at a
time, in the order shown, restarting the
system-board tray each time:
a. DIMM
b. (Trained service technician only)
System-board tray