10. Remove the DIMMs (see "Removing a memory module" on page 106).
11. Remove the microprocessors and heat sinks (see "Removing a microprocessor
12. If you are instructed to return the system-board tray, follow all packaging
152
System x iDataPlex dx340 Types 6385, 6386, 6389, 7831, 7832, and 7834: Problem Determination and Service Guide
3. If an expansion enclosure is installed, remove it (see "Removing an expansion
enclosure from a system-board tray" on page 73); otherwise, remove the
system-board tray cover (see "Removing the system-board tray cover" on page
121).
4. Remove the hard disk drives, if any are installed (see "Removing and installing
a hard disk drive" on page 88).
5. Remove the hard disk drive bracket and cable assembly (see "Removing and
installing a one-bay or four-bay hard disk drive bracket and cable assembly" on
page 108).
6. Remove the 2.5-inch hot-swap drive cage, if one is installed (see "Removing a
2.5-inch hot-swap drive cage" on page 96).
7. Remove the PCIe adapters, if any are installed (see "Removing an adapter
from the system-board tray" on page 100).
8. Remove the riser card (see "Removing a PCIe riser-card assembly from the
system-board tray" on page 115).
9. Remove the battery from the system board (see "Removing the battery" on
page 86).
and heat sink" on page 141).
instructions, and use any packaging materials for shipping that are supplied to
you.