Error
Cause
FAILED
(Shorted)
E-10 (A
High limit tripped.
thru Y)
E-15C
The drain valve
DRAIN
doesn't fully closed.
VALVE
ERROR
E-15P
The drain valve
DRAIN
doesn't fully open.
VALVE
ERROR
E-18A LE-
The oil level probe
VEL SEN-
has failed.
SOR
FAILED
(Open
Circuit)
E-18B LE-
VEL SEN-
SOR
FAILED
(Shorted)
E-19 PRO-
TECTION
PROBE
FAILED
E-41P-1-
System data lost.
LOST
Both the RAM copy
and stored copy of
the settings have
been lost. Settings
are reset to default.
Correction
Reset the high limit trip. The reset momentary switch is
below the control panel heat vents, under the lip, above
the condensation tank (box). Perform a clean out, refer
to
6.7 Clean-Out Mode , page
call for service.
T T R R A A I I N N I I N N G G
:E-10 Error explanation.
Unclog the drain with a drain brush. If the error persists
call for service.
Check drain for an obstruction. If the error persists call
for service.
Call for service.
Call for service.
Call for service.
45. If the error persists
81