Henny Penny KFC Velocity Series Operation Manual page 76

Hide thumbs Also See for KFC Velocity Series:
Table of Contents

Advertisement

Program
Code
FC-5
FC-6
FC-7
FC-8
66
Display
QUICK FILTER: FILTER:
DRAIN POSITION
QUICK FILTER: FILL: DETECT
AT LEVEL PROBE, KEEP
PUMPING
QUICK FILTER: NORMAL FILL
TIME
QUICK FILTER: FILL: NO DE-
TECT: MAX PUMP
Description
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
At the end of the Drop cycle, controls how far
the drain closes to a partially open position.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
When refilling the pot, controls how long to
keep pumping after the oil initially reaches or
splashes on the upper probe and the ex-
pected temperature rise is observed.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
The expected time it takes to refill the vat at
the end of a Quick Filter.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
If the fryer pumps for this amount of time dur-
ing the Fill phase without observing a tem-
perature rise on the upper temperature
probe, the control turns the pump off, and
asks IS POT FILLED?.
1 1 . . Enter a new value by using the product
numbers.