Program
Display
Code
FC-43
DISPOSE: DROP OIL: DRAIN
OPENING
FC-44
ALWAYS ASK, IS POT
FILLED?
FC-45
ANY FILL: NOT FILLED, EX-
TRA PUMP TIME
D D i i s s p p o o s s e e S S e e t t t t i i n n g g s s
This setting specifies the drain opening to be
used when draining the oil to a disposal cart,
shuttle, or bucket for disposal. (Does not ap-
ply to Bulk Dispose operations.)
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
M M i i s s c c e e l l l l a a n n e e o o u u s s S S e e t t t t i i n n g g s s
This option can be engaged to always ask –
at the end of each Quick Filter, Auto Mix, and
Polish operation, if the pot is filled. Normally,
the control asks IS POT FILLED? only if it
has pumped for a long time attempting to fill
the pot, but no temperature rise was ob-
served on the upper temperature probe.
Press the + or - button to select either YES
or NO.
When refilling the pot at the end of a Quick
Filter, Auto Mix, or Polish operation, the con-
trol closes the drain and runs the pump until
a suitable temperature rise is observed on
the upper temperature probe (the level
probe). If no temperature rise is seen after
pumping for a reasonable maximum pump-
ing time, the control stops, turns the pump
off, and asks IS POT FILLED?.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
Description