Program
Display
Code
FC-21
AUTO TOP OFF: AFTER 'X'
ATTEMPTS, CHECK ATO
FC-22
COOK MODE - FORCED ATO
CHECK AFTER 'X' COOKS
FC-23
START-UP: NEEDED IF TEMP
< 'X'
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
After each ATO pulse, the control monitors
the level probe temperature to see if the oil
has been brought up to the proper level. If
not, a second ATO pulse is given. After a
certain number of pulses, as specified by this
setting, if the oil level still has not been
brought up to the proper level, the control
beeps and displays FILL OIL TANK.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
Controls the number of cook cycles before
forcing a check of the ATO.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
S S t t a a r r t t - - u u p p M M o o d d e e S S e e t t t t i i n n g g s s
If the oil temperature is below 215° F when
the fryer is turned on, the fryer always exe-
cutes a Melt Mode regardless of the Start-up
Needed setting. Sets temperature base to in-
itiate a Start-up.