To protect community sewer lines, oil must be trapped and
disposed of through bulk removal. Hot oil can coagulate when
NOTICE
cooled, which clogs pipes and sewer lines. Always dispose of
oil in to an approved bulk oil disposal storage container or
:
approved grease trap. Never pour oil down a public sanitation
drain.
6 6 . . 6 6 . . 4 4 . . 1 1 A A c c c c e e s s s s t t h h e e D D i i s s p p o o s s e e M M e e n n u u
Use the following steps to access the disposal menu. An indicator light displays next
to active options during procedure.
Press and hold the M M a a i i n n menu button until *MAIN* displays. The Main menu
1 1 ) )
displays.
Press the 1 1 . . F F I I L L T T E E R R button. Additional menu items display.
2 2 ) )
Press the M M a a i i n n menu button twice. The dispose menu displays.
3 3 ) )
6 6 . . 6 6 . . 4 4 . . 2 2 F F r r o o n n t t D D i i s s p p o o s s a a l l R R e e m m i i n n d d e e r r - - C C o o n n n n e e c c t t t t h h e e H H o o s s e e
I I N N F F O O : Rear dispose systems should always have the hose connected to the fryer, so
no such reminder displays.
If set for front disposal (hose), the control displays a reminder to connect the hose
between the fryer and the disposal cart (tank). Confirm that the hose is securely
connected on both ends—at the tank and at the fryer—then press the Y Y E E S S button to
proceed.
6 6 . . 6 6 . . 4 4 . . 3 3 D D r r a a i i n n t t h h e e O O i i l l
Drain the oil from the vat by doing the following:
Press the 7 7 . . D D I I S S P P O O S S E E button. The message DRAIN POT? and YES NO
1 1 ) )
displays.
Press the Y Y E E S S button. DRAINING displays.
2 2 ) )
Wait. The oil from the vat drains in to the drain pan. When complete, the
3 3 ) )
message =PURGE= Pump new oil push old oil from ports displays.
6 6 . . 6 6 . . 4 4 . . 4 4 P P u u r r g g e e t t h h e e F F i i t t t t i i n n g g s s
Degraded oil remains inside the lines, valves and fittings. To completely purge the
degraded oil, do the following:
Press the P P U U M M P P button. The pump runs for a few seconds, new oil pumps in to
1 1 ) )
the vat, then the pump stops.
If necessary, press the P P U U M M P P button again to ensure the lines, valves and
2 2 ) )
fittings are purged.
6 6 . . 6 6 . . 4 4 . . 5 5 W W i i p p e e O O u u t t t t h h e e V V a a t t
To ensure degraded oil does not mix with new oil, do the following:
Put on Personal Protective Equipment (PPE).
1 1 ) )
43