Henny Penny KFC Velocity Series Operation Manual page 80

Hide thumbs Also See for KFC Velocity Series:
Table of Contents

Advertisement

Program
Code
I I N N F F O O : If X pulses of oil have not brought the level up, the control assumes that the oil tank is
empty—that no oil is being pumped into the pot—and displays FILL OIL TANK. If the fryer is
configured to use a Bulk Oil Supply system, the message displayed is CHECK BULK OIL
SUPPLY rather than FILL OIL TANK. In this case, it is possible that the remote bulk supply
tank is empty, that the bulk supply plumbing connection is not connected to the fryer, or that
the bulk supply electrical connection is not connected.
FC-18
FC-19
FC-20
70
Display
A A u u t t o o T T o o p p O O f f f f S S e e t t t t i i n n g g s s
AUTO TOP OFF: ENABLED?
AUTO TOP OFF: PUMP TIME
AUTO TOP OFF: REPEAT
Description
3 3 . . Press "X" to return to default or previous
setting.
Enables or disables all Auto Top Off (ATO)
operations.
1 1 . . Press the + or - button to select either
YES or NO.
Disabling the Auto Top Off feature would nor-
mally be done only if the top off system itself
has failed, in order to avoid the FILL OIL
TANK messages that occur if the fryer
doesn't detect oil at the proper level after 3
attempts.
Specifies how long the ATO pump runs for
each individual ATO pulse.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
This setting may be manually adjusted as
needed. Ideally, each ATO pulse pumps
about 1/8" (3.175 mm) to 3/16" (5 mm) of
fresh oil into the pot.
Specifies how long the control waits before
assessing the oil level and generating a sec-
ond ATO pulse if the oil level is still low.