Henny Penny KFC Velocity Series Operation Manual page 67

Hide thumbs Also See for KFC Velocity Series:
Table of Contents

Advertisement

Menu Item
Function
CPU Info
Displays live temperature reading for the CPU (controller), software ver-
(Information)
sion, and software part number.
Temperatures
Displays live readings for main oil, level probe, and the bottom of vat
temperature.
(Digital) Inputs-
✓ - Signal present
1
- - No signal present
A - Power Switch
H - High Limit
D - Drain Switch Jumper
S - Power Switch Interlock
F - Fan Switch Jumper
(Digital) Inputs-
✓ - Signal present
2
- - No signal present
24dc - 24 DC Supply
Pan - Filter Drain Pan
*Lid - Lid Liner Pin
Lid Liner Pin shows OK if pin is down
Lid Liner Pin shows PR when pin is raised (under pressure)
(Bulk Oil) In-
✓ - Signal present
puts-3
- - No signal present
DTF - Discard Tank Full
FULL - Discard tank is full and cannot dispose to it
OK - Discard tank not full, okay to dispose
Pressure Inputs
n/a
Manifold
Displays pump pressure reading if optional transducer is installed in
Pressure
plumbing manifold as:
* - On
- - Off
otherwise displays NO SENSOR.
Fryer Outputs
* - On
- - Off