Technical Specifications - Ph Sensor - Priva Compass Installation Manual

Table of Contents

Advertisement

Priva
Technical specifications – pH sensor
Article description
Article number
Housing
Length of sensor
Diameter of sensor
Measurement principle
Discrimination
Operating range (measured values satisfy
the specified accuracy)
Range (sensor produces measured values)
Accuracy (after calibration)
Cable
Connector
86
pH sensor (max. 10.0 bar)
3779046
glass
77 mm
Ø 12 mm (Ø 15 mm with protective cover)
+
pH electrode for H
ions
59 mV/pH (in operating range 4 .. 7 pH at 25 ˚C)
4 .. 7 pH
3 .. 14 pH
± 0.1 pH (in operating range 4 .. 7 pH at 5 .. 30 ˚C)
coax, Ø 2.5 mm, length 3 m
BNC