Material
Dimensions
Weight
Type of protection
Type of connection
Sensors (in combination with Compass)
Available measurements in combination with Compass
Sensors
Wind speed
Type
Measuring range
Resolution
Accuracy
Wind direction
Type
Measuring range
Resolution
Accuracy with laminar incident flow
Light (north, east, south, west)
Type
Measuring range
Resolution
Accuracy
Spectral range
Twilight
Type
Measuring range
Resolution
Accuracy
Global irradiance
Type
Measuring range
Resolution
Accuracy
Installing Priva Compass - 00.014
Priva weather station WSC11
Polycarbonate
See Dimension drawing
0.22 kg
IP65 in working position
7-pin plug connector
Wind speed
Wind direction
Global radiation (Radiation sensor)
Rain alarm
Outside temperature
Relative humidity
Thermal anemometer
0 ... 40 m/s
0.1 m/s
To 10 m/s: ±1 m/s (rms - mean over 360°).From 10m/s:
±5 % (rms - mean over 360°).
Thermal anemometer
1 ... 360°
±10°
Silicon sensor
0 ... 150 kLux
0.1 kLux
±3% (± 4.5 kLux)
475 ... 650 nm
Spectrum of light sensors/Directional characteristics of
light sensors
(Source: data sheet for component SFH5711 / OSRAM)
Silicon sensor
0 ... 999 Lux
1 Lux
±10 Lux
Silicon sensor
0 ... 1300 W/m2
1 W/m2
±10 % (± 130 W/m²)
49