Measurements
Nett weight
This measurement value shows the actual nett weight which is currently resting on the weighing
unit. This weight is passed to the process computer via the analog outputs. This menu item will
become active automatically after you have started up the indicator or if no operations are performed
for 15 minutes.
# of Load Cells
This shows the number of weighing platforms entered into the weighing indicator. This number
should match the actual number of weighing platforms being used (i.e. 2 or 4).
Tare Weight
This figure indicates the weight in relation to the absolute zero point of the weighing indicator. This
information is gained after performing the Set tare Weight function in Load Cells or Slab calibration.
After finishing with the Slab calibration menu, this figure shows the weight of the unit while only
incorporating a dry slab. This information must be entered on the accompanying form so it can be
entered into any new weighing indicator without first having to calibrate the unit (please also refer
to the menu Service).
Saturated Slab
This figure indicates the weight of saturated substrate slab after using the function Saturated Slab
from the Slab calibration menu. This information must be entered on the accompanying form.
Max #kg/5V
This figure indicates the maximum nett weight in number of kg set by you and which can be passed
to the process computer. It should match an output signal of 5000 mV from the first analog output.
The maximum nett weight to be weighed must never exceed this value.
Display
In this menu, the contrast and choice of language can be set:
Contrast
This allows you to set the contrast between 0 - 100%, which means optimum readability can be
obtained under different light and temperature conditions. This value has a default of 50%.
Language select
This allows you to set the language to Dutch, English, German or French.
Installing Priva Compass - 00.014
Groscale
113