Troubleshooting your Avaya CallPilot® system
Update OK!
Updated Failed
Keyboard Error
KB/Interface Error
Memory Size Decreased
Memory Size Increased
Memory Size Changed
No Boot Device Available
Off-Board Parity Error
On-Board Parity Error
Parity Error
NVRAM / CMOS / PASSWORD cleared by
Jumper
<CTRL_N> Pressed

Replacement parts

Before replacing any parts on your server, refer to the Avaya product catalog for the part codes.
Caution:
Risk of system damage
26
Avaya CallPilot® 600r Server Maintenance and Diagnostics
Error message
Description
The NVRAM is invalid and has been
updated.
The NVRAM is invalid and the system cannot
update NVRAM.
There is an error in the keyboard connection.
Make sure the keyboard is connected
properly.
The keyboard interface test failed.
The memory size has decreased since the
last boot. If you did not remove any memory,
the memory can be faulty.
The memory size has increased since the
last boot. If you have not added any memory,
there is a problem with the system.
The memory size has changed since the last
boot. If you did not add or remove any
memory, the memory can be faulty.
The system did not find a device to boot from.
A parity error occurred on an off-board card.
This error is followed by the card address.
A parity error occurred in the on-board
memory. This error is followed by the card
address.
A parity error occurred in the on-board
memory at an unknown address.
NVRAM, CMOS, and passwords are
cleared. Power the system down and remove
the jumper.
The CMOS is ignored and NVRAM is
cleared. You must enter Setup.