Operating Limits - Nice Spin Series Instructions And Warnings For The Fitter

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

2.1) Operating limits

Chapter 8 "Technical Characteristics" provides the data needed to determine whether the products of the SPIN line are suitable for the intend-
ed application.
The structural characteristics of the SPIN products make it suitable for use on sectional and overhead doors within the limits shown in Tables
3, 4 and 5.
Table No. 3: SPIN gearmotor operating limits
Model:
Height
SPIN20KCE
2.4m
SPIN21KCE
2.4m
SPIN30
2.4m
SPIN40
2.4m
SN6031 (SNA5)
2.4m
SN6031 (SNA6)
3.4m
SN6041 (SNA6)
3.4m
The measurements in table N° 3 are guideline only and can be used as a general estimate only. The effective suitability of SPIN for automat-
ing a specific door depends on the degree of door leaf balancing, guide friction and other aspects, including occasional phenomena such as
wind pressure or the presence of ice, which could obstruct leaf movement.
To establish effective conditions, the force required to move the leaf throughout its stroke must be measured, to ensure that this value does
not exceed the "rated torque" specified in chapter "8 Technical specifications"; also, to calculate the number of cycles/hour and consecutive
cycles, the data in tables 4 and 5 must be taken into account.
Table 4: limits related to leaf height
Leaf height
Max. 2
2÷2,5
2,5÷3
3÷3,5
Table N°5: limits in relation to force required to move door leaf
Force required to move leaf N
Max. 250
250÷400
400÷500
500÷650
650÷850
The height of the door enables a calculation of the maximum number of cycles per hour and consecutive cycles, while the force required to
move the door enables a calculation of the percentage of cycle reduction; for example, if the leaf height is 2.2 m this would enable 15 cycles
per hour and 7 consecutive cycles, but if a force of 300N is required, using a SN6021 gearmotor, these would have to be reduced to 70%,
resulting therefore in 10 cycles per hour and around 5 consecutive cycles. To avoid overheating, the control unit has a limiter that is based
on the motor operation and duration of cycles, and trips when the maximum limit is exceeded.
N.B. 1Kg = 9.81N, meaning that 500N, for example, is equivalent to 51Kg.
4
SECTIONAL door
OVERHEAD door, non-protruding
Width
4.4m
4.4m
4.4m
5.2m
4.4m
3.1m
5.2m
Max. no. of cycles/hour
20
15
12
10
Cycle reduction percentage
SN6021 - SN6031
100%
70%
25%
---
---
(with accessory SPA5)
Height
Width
2.2m
4.2m
2.2m
4.2m
2.2m
4.2m
2.2m
4.2m
2.2m
4.2m
3.2m
2.9m
3.2m
4.2m
Max. no. of consecutive cycles
10
7
5
4
SN6041
100%
90%
70%
40%
25%
OVERHEAD door, protruding (with accessory
SPA5) or with springs (without SPA5)
Height
2.8m
2.8m
2.8m
2.8m
2.8m
3.5m
3.5m
Width
4.2m
4.2m
4.2m
4.2m
4.2m
3.4m
4.2m