Recognition Of Other Devices; Special Functions; Always Open" Function; Move Anyway" Function - Nice Spin Series Instructions And Warnings For The Fitter

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

7.3.4) Recognition of other devices

Normally the recognition of the devices connected to the BlueBUS and the STOP input takes place during the installation stage. However, if
new devices are added or old ones removed, the recognition process can be gone through again by proceeding as follows:
Table 22: Recognition of Other Devices
1.
Press keys [s] and [Set] and hold them down [Set] x 3s
2.
Release the keys when L1 and L2 LED's start flashing very quickly (after approx. 3 s)
3.
Wait a few seconds for the control unit to finish recognizing the devices
4.
When the recognition stage is completed L1 and L2 LED's will go off, the STOP LED must remain on,
while L2...L4 LED's will light up according to the status of the relative ON-OFF functions.
After you have added or removed any devices, the automation system must be tested again according to the directions
!
contained in paragraph 5.1 "Testing".

7.4) Special Functions

7.4.1) "Always Open" Function

The "Always open" function is a control unit feature which enables
the user to control an opening manoeuvre when the "Step-by-Step"
command lasts longer than 3 seconds. This is useful for connecting
a timer contact to the "Step-by-Step" terminal in order to keep the
door open for a certain length of time, for example. This feature is
valid with any kind of "Step-by-Step" input programming. Please
refer to the "Step-by-Step Function" parameter in Table 17.

7.4.2)"Move anyway" function

In the event that one of the safety devices is not functioning proper-
ly or is out of use, it is still possible to command and move the door
in "Man present" mode. Please refer to the Paragraph "Control with
safety devices out of order" in the enclosure "Instructions and Warn-
ings for users of the SPIN gearmotor" for further information.
7.5 Connection to other devices
If the user needs to feed external devices such as a proximity read-
er for transponder cards or the illumination light of the key-operated
selector switch, it is possible to tap power as shown in Figure 46.
The power supply voltage is 24Vdc -30% - +50% with a maximum
available current of 100mA
-
46
24Vcc
Example
SET
SET
L1
L2
L1
L2
+
21
GB
GB

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spin21kceSpin30Spin20kceSn6031Sn6041Spin40

Table of Contents