Signals On The Control Unit - Nice Spin Series Instructions And Warnings For The Fitter

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

7.7.2) Signals on the control unit

On the SPIN control unit there is a set of LED's each of which can
give special indications both during normal operation and in case of
malfunctions.
Table 25: LED's on the control unit's terminalsle
BLUEBUS Led
Off
On
One flash every second
2 Quick flashes
Series of flashes separated by a
second's pause
STOP LED
Off
On
STEP-BY-STEP LED
Off
On
Table 26: LED's on the control unit's keys
L1 LED
Off
On
Flashing
L2 LED
Off
On
Flashing
L3 LED
Off
On
Flashing
L4 LED
Off
On
Flashing
Cause
Malfunctionaa
Serious malfunction
Everything OK
The status of the inputs has
changed
Miscellaneous
Cause
Activation of the STOP input
Everything OK
Cause
Everything OK
Activation of the STEP-BY-
STEP input
Description
During normal operation the device indicates "Automatic Closure" is inactive.
During normal operation the device indicates "Automatic Closure" is active.
• Function programming in progress
• If it flashes together with L2, it means that it the user must carry out the device recognition phase (refer
to Paragraph "4.3 Recognition of the devices").
Description
During normal operation the device indicates "Close after photo" is inactive.
During normal operation the device indicates "Close after photo" is active.
• Function programming in progress
• If it flashes together with L2, it means that it the user must carry out the device recognition phase (refer
to Paragraph "4.2 Recognition of the devices").
Description
During normal operation the device indicates "Motor Force" for "heavy" doors.
During normal operation the device indicates "Motor force" for light "doors"
• Function programming in progress
• If it flashes together with L4 it means that the user must carry out the door opening and closing posi-
tions recognition phase (refer to Paragraph "4.3 Recognition of the door opening and closing positions").
Description
During normal operation the device indicates "Stand-by" is inactive.
During normal operation the device indicates "Stand-by" is active.
• Function programming in progress
• If it flashes together with L3 it means that it the user must carry out the leaf length recognition phase
((refer to Paragraph "4.3 Recognition of the door opening and closing positions").
48
ACTION
Make sure there is power supply; check to see if the fuses are blown; if necessary, identify the
reason for the failure and then replace the fuses with others having the same characteristics.
There is a serious malfunction; try switching off the control unit for a few seconds; if the con-
dition persists it means there is a malfunction and the electronic board has to be replaced
Normal operation of control unit
This is normal when there is a change in one of the inputs: STEP-BY-STEP,
STOP, triggering of photocells or the radio transmitter is used
It corresponds to the flashing light's or the courtesy light signal. See table 24
ACTION
Check the devices connected to the STOP input
STOP Input active
ACTION
STEP-BY-STEP input not active
This is normal if the device connected to the STEP-BY-STEP input is actually
active
GB
GB
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spin21kceSpin30Spin20kceSn6031Sn6041Spin40

Table of Contents