4. Set Up BQ-260
4-1 Nipper Unit Set Up
NOTE
When your binding job is pad binding
(without cover), nipper unit set up is not
necessary to perform. Select pad binding
mode with nipping mode select switch. Then
proceed to "4-2 Clamper Unit Set Up" in
Page 26.
4-1-1 Nipper Unit Set Up for Stock Thickness
This section shows how to adjust nipping
width against stock thickness.
WARNING
Do not touch melt tank unit when
adjusting nipper unit. Melt tank is
heated up around 200˚C. High tem-
perature can cause severe skin burn.
1.
Select either with milling or without
milling binding mode by nipping mode
select switch.
Near Side : for signature binding
Far Side : for with milling binding
Center :
for pad binding
2.
Depress nipper up/down button to raise
nipper plate. Nipper plate stop at upper
position.
NOTE
- Nipper jaw's width must be adjusted when
nipper unit is at upper position.
- When nipper up/down button is depressed
with nipper being up position, nipper unit will
be down.
- Nipper is at lower position when 5 screws
on nipper plate appear.
3.
Depress stop button.
Nipper Up/Down Button
22
Nipping Mode
Select Switch
Screws