3-1 Safety Device Function Check
4.
Check safety cover function.
- Stand in front of operation panel.
- Hold handle on safety cover with your
both hand to prepare to open safety cover
immediately
- Depress start button and open safety cover
1 second after start button was depressed.
- Clamper will stop in a moment to show
that safety cover function works correctly.
NOTE
When clamper does not stop in a moment
even if safety cover is opened, turn off main
power and call your local dealer.
5.
Move clamper to home position.
- Close safety cover.
- Depress start button to move clamper to
its original position. Clamper will stop
over nipping unit for 10 seconds.
6.
Reset level plate.
- When clamper returns to home position,
depress level plate button once to reset
level plate.
- Start button will turn on to indicate
level plate is reset.
7.
Depress stop button to prevent BQ-260
works suddenly by mistake.
Safety Cover
Start Button
Level Plate
Button
LED for Stop Button
Clamper
Stop Button
17
3. Before Starting Operation
Handles
Cover Feeder
Unit