8. Maintenance
8-2 As Required

8-2-3 Glue Draining

This section shows how to drain glue in melt
tank. Deteriorated glue because of long
heating will cause decrease of adhesive
strength.
WARNING
Ware gloves on your hands when glue
is drained. Melted glue temperature is
200˚C. It can cause sever skin barn.
NOTE
Glue can only be drained when it is melted.
1.
Melt glue.
- Turn on main power and wait until LED
for melt tank on monitor turns off.
2.
Attach glue drain.
- Remove melt tank cover.
- Open control box.
- Attach glue drain under drain plate.
3.
Provide a box for receiving glue (2 liter
capacity).
4.
Drain glue
- Remove drain plug. Glue will come out
from melt tank.
- Fasten drain plug after all glue are
drained.
5.
Close covers
- Remove glue drain.
- Close control box , melt tank cover and
safety cover.
Met Tank Cover
66
Control Box
Drain Plate
Glue Drain
Box