B.2 Parameter Table
No.
Name
This parameter sets the dead-band width around each
Jump
selected prohibited frequency reference point. The
d3-04
Frequency
bandwidth becomes the designated Jump frequency,
Width
plus or minus d3-04.
Use d4 parameters to configure the drive frequency reference hold function.
Determines if the frequency reference or frequency
reference bias is saved when the Run command is
removed or the power goes off.
Frequency
0: Disabled
Reference
d4-01
1: Enabled
Hold Function
This parameter is effective when the multi-function
Selection
inputs "Accel/Decel Ramp Hold", "Up/Down" or
"Up/Down 2" commands are selected (H1-oo = A
or 10/11).
<19>
Range upper limit is dependent on parameters E1-04, Maximum Output Frequency, and d2-01, Frequency
Reference Upper Limit.
<22>
Parameter can be changed during run.
u

E: Motor Parameters

E parameters set V/f characteristics and motor-related data.
No.
Name
This parameter must be set to the power supply
voltage.
E1-01
Input Voltage
WARNING! Drive input voltage (not motor voltage)
Setting
must be set in E1-01 for the protective features of the
<24>
drive to function properly. failure to do so may result
in equipment damage and/or death or personal injury.
E1-03 V/f Pattern
F: Custom V/f. E1-04 through E1-10 settings define
Selection
the V/f pattern.
204
YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual
Description
d4: Frequency Reference Hold
Description
E1: V/f Pattern Characteristics
Use E1 parameters to set V/f characteristics for the motor.
Mode Addr.
Range Def.
V/f
0.0 to
1.0
O
20.0
Hz
0, 1
0
O
Mode Addr.
Range Def.
V/f
155 to
<14>
S
255
F
F
O
Pg.
Hex
297
298
Pg.
Hex
300
99
302