YASKAWA CIMR-JA Series Installation & Start-Up Manual page 215

Compact v/f control drive
Hide thumbs Also See for CIMR-JA Series:
Table of Contents

Advertisement

No.
Name
Selects if the ENTER key must be pressed when
Frequency
inputting the frequency reference by the operator
Reference
keypad.
o2-05
Setting
0: Data/Enter key must be pressed to enter a frequency
Method
reference.
Selection
1: Data/Enter key is not required. The frequency
reference is adjusted by the UP and DOWN keys.
Initialization
o2-09
(Maker setting)
mode
Use o3 parameters to Read, Copy and Verify the parameter settings to and from the drive.
Changes some parameter default settings depending
on the region.
This parameter controls the copying of parameters to
and from the LED operator (option).
0: COPY SELECT (no function)
1: INV --> OP READ - All parameters are copied from
Copy Function
the drive to the LED operator.
o3-01
Selection
2: OP --> INV WRITE - All parameters are copied
from the LED operator to the drive.
3: OP<-->INV VERIFY - Parameter settings in the
drive are compared to those in the LED operator.
NOTE: When using the copy function, the drive
model number (o2-04) and the software number
(U1-14) must match or an error will occur.
Enables and disables the digital operator copy
functions.
Copy Allowed
o3-02
0: Disabled - No digital operator copy functions are
Selection
allowed.
1: Enabled - Copying allowed.
Accumulated
Sets the value for the cumulative operation time of the
o4-01
Operation
drive in units of 10 h.
Time Setting
Determines, how the cumulative operation time
Accumulated
(U4-01) is counted.
Operation
o4-02
0: Logs power-on time
Time
1: Logs operation time when the drive output is active
Selection
(output operation time).
Cooling Fan
Sets the value of the fan operation time monitor U4-03
o4-03
Operation
in units of 10 h.
Time Setting
Capacitor
Sets the value of the capacitor maintenance time
o4-05
Maintenance
monitor U4-05.
Setting
Soft Charge
Bypass Relay
Sets the value of the Soft Charge Bypass Relay
o4-07
Maintenance
Maintenance monitor U4-06.
Setting
YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual
Description
o3: Copy Function
o4: Maintenance Period
Use o4 parameters to perform maintenance.
B.2 Parameter Table
Mode Addr.
Range Def.
V/f
0, 1
0
O
dep.
on
0 to 3
O
drive
spec.
0 to 3
0
O
0, 1
0
O
0 to 9999
0
O
0, 1
0
O
0 to 9999
0
O
0 to 150
0%
O
0 to 150
0%
O
Pg.
Hex
509
50D
515
516
50B
50C
50E
51D
523
B
215