Removing The Fan Bracket - IBM Storwize V7000 Unified Problem Determination Manual

Table of Contents

Advertisement

2. Align the air baffle pins with the two baffle pin slots on both sides of chassis.
3. Lower the air baffle into place, making sure that all cables are out of the way.
Press the air baffle down until it is securely seated.
Note: Close the retaining clip on each end of the DIMM connector before you
install the air baffle.
4. Install the cover. For more information, see Installing the cover.
5. Slide the file module into the rack.
6.
Follow the steps at the end of the procedure in "Removing a file module and
disconnecting power" on page 58 to suspend the file module to reconnect the
file module and resume its use in the cluster.
Results
Attention: For proper cooling and airflow, replace all air baffles before you turn
on the file module. Operating the file module with any air baffle removed might
damage file module components.

Removing the fan bracket

The following procedure is for a Tier 1 customer replaceable unit (CRU).
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation. Service agreements can be
purchased so that you can ask IBM to replace these units.
About this task
To replace some components or to create working room, you might have to remove
the fan-bracket assembly.
Note: To remove or install a fan, it is not necessary to remove the fan bracket.
To remove the fan bracket, complete the following steps.