5. Install the cover, as described in "Installing the cover" on page 84.
6. Slide the file module into the rack.
7. Reconnect the external cables; then, reconnect the power cords and turn on the
file module.
Note: You must wait approximately 20 seconds after you connect the power
cord of the file module to an electrical outlet before the power-control button
becomes active.
Attention: For proper cooling and airflow, replace all air baffles before you
turn on the server. Operating the server with any air baffle removed might
damage server components.

Removing the fan bracket

The following procedure is for a Tier 1 customer replaceable unit (CRU).
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation. Service agreements can be
purchased so that you can ask IBM to replace these units.
Note: Before running a procedure, refer to "Removing a file module to perform a
maintenance action" on page 51.
To replace some components or to create working room, you might have to remove
the fan-bracket assembly.
Note: To remove or install a fan, it is not necessary to remove the fan bracket. See
"Removing a hot-swap fan" on page 133 and "Installing a hot-swap fan" on page
134.
To remove the fan bracket, complete the following steps.
95
Chapter 4. File module