IBM Storwize V7000 Unified Problem Determination Manual page 57

Table of Contents

Advertisement

Table 12. Error code port location mapping (continued)
Error code
Description
4B0803C
Slow connection on
Fibre Channel
adapter 1, port 1.
4B0804C
Slow connection on
Fibre Channel
adapter 1, port 2.
To enable the LED indicator for the node reporting the problem, use the
Monitoring > System page in the management GUI or follow this procedure:
1. Log onto the active file module via the CLI interface.
2. Run the command: locatenode #HOSTNAME on #SECONDS. HOSTNAME is the
hostname associated with the error... either mgmt001st001or mgmt002st001.
#SECONDS is the number of seconds for the LED indicator to be turned on.
Physical connection and repair:
Each file module has a dual port Fibre Channel adapter card located in PCI slot 2.
Both ports are used to connect to the Storwize V7000 system with a connection
going to each Storwize V7000 node canister.
Table 13. Fibre Channel cabling from the file module to the control enclosure.
File Module Node # 1
PCI slot #2, port 1
PCI slot #2, port 2
Connects to Storwize
Connects to Storwize
V7000
V7000
Lower canister –
Upper canister –
Fibre Channel port 1
Fibre Channel port 1
If a problem is detected with a Fibre Channel path between the storage node and
the control enclosure, check the LED indicators next to the Fibre Channel
connection ports on both the file module and the Storwize V7000 node canister.
Table 14. LED states and associated actions. For the Fibre Channel adapters on the file
module check the amber LED lights next to the port.
LED State
Solid amber LED
Slow flashing amber LED
Storage Node
File Module Fibre
Canister Fibre
Channel Location
Channel Port
PCI slot #2 – port 1
Upper node canister,
(right port when
port 1. OR upper
facing rear of system)
node canister, port 2.
PCI slot #2 – port 2
Lower node canister,
(left port when facing
port 1. OR lower
rear of system)
node canister, port 2.
File Module Storage Node # 2
PCI slot #2, port 1
PCI slot #2, port 2
Connects to Storwize
Connects to Storwize
V7000
V7000
Lower canister –
Upper canister –
Fibre Channel port 2
Fibre Channel port 2
Definition and Action
This state indicates a good connection status.
This state indicates a good connection at the
Fibre Channel port but a broken connection
at the Storwize V7000 node canister. This
broken connection is most likely either a
Fibre Channel cable or the Fibre Channel
port is bad on the Storwize V7000 node
canister.
Chapter 3. Getting started troubleshooting