IBM Storwize V7000 Unified Problem Determination Manual page 62

Table of Contents

Advertisement

Table 16. LED indicators, corresponding problem causes, and corrective actions (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be completed only by a trained
technician.
LED
Problem
PCI
An error occurred on a PCI card,
a PCI bus, or on the system
board. An extra LED is lit next to
a failing PCI slot.
NMI
An interrupt that cannot be
masked occurred, or the NMI
button was pressed.
42
Storwize V7000 Unified: Problem Determination Guide 2073-720
Action
1. If the CONFIG LED is not lit, complete the following
steps to correct the problem:
a. Check the riser-card LEDs, the ServeRAID error LED,
and the optional network adapter error LED to
identify the component that caused the error.
b. Check the system-error log for information about the
error.
c. If you cannot isolate the failing component by using
the LEDs and the information in the system-error log,
remove one component at a time; and restart the file
module after each component is removed.
d. Replace the following components, in the order that is
shown, restarting the file module each time:
v PCI riser cards
v ServeRAID adapter
v Optional network adapter
v (Trained technician only) System board
e. If the failure remains, go to http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008&lndocid=SERV-CALL.
2. If the PCI LED and the CONFIG LED are lit, complete the
following steps to correct the problem:
a. Check the microprocessor that is installed is Intel
E5-2690.
b. Remove the high-power (>25 Watt) adapter.
c. Check the system-error logs for information about the
error. Replace any component that is identified in the
error log.
1. Check the system-error log for information about the
error.
2. Restart the file module.