Removing A Microprocessor And Heat Sink - IBM Storwize V7000 Unified Problem Determination Manual

Table of Contents

Advertisement

SAS
signal
cable
Configuration
cable
Figure 33. Installing the hot-swap drive backplane
Procedure
1. Connect the power and signal cables to the replacement backplane.
2. Align the backplane with the backplane slot in the chassis and the small slots
3. Lower the backplane into the slots on the chassis.
4. Rotate the top of the backplane until the front tab clicks into place into the
5. Insert the hard disk drives and the fillers the rest of the way into the bays.
6. Replace the fan bracket and fans if you removed them.
7. Install the cover. For more information, see Installing the cover.
8. Slide the file module into the rack.
9. Follow the steps at the end of the procedure in "Removing a file module and

Removing a microprocessor and heat sink

IBM authorized service providers can remove and replace a microprocessor and
heat sink in the file module. The following procedure is for a field replaceable unit
(FRU). FRUs must be installed only by trained service technicians.
Power
cable
on top of the hard disk drive cage.
latches on the chassis.
disconnecting power" on page 58 to suspend the file module to reconnect the
file module and resume its use in the cluster.
Hard disk drive
backplane
131
Chapter 4. File module