General Data; A.2.2 General Data - Siemens SIMATIC VS130 Series Manual

Vision sensor
Table of Contents

Advertisement

A.2.2

General Data

Power Supply
Supply voltage (U
)
N
Input voltage protected
against polarity reversal
Voltage loss (can be
bridged)
Current consumption (I
)
N
Fuse
Making current
Safety requirements complying
with
Electromagnetic Compatibility (EMC)
Pulse-shaped interference
Interference
Electrostatic discharge
according to IEC 61000-4-2
Burst pulse (fast transients)
complying with IEC 61000-4-4
Surge complying with IEC 61000-4-5
Coupling
Asymmetrical
Symmetrical
Sine-shaped disturbance
Radio frequency
electromagnetic fields
complying with IEC 61000-4-3
complying with IEC 61000-4-3
RF interference on
cable/cable shields
complying with IEC 61000-4-6
Vision Sensor VS 130
A5E00199459-01
DC24 V; (DC20.4...DC28.8 V, safety extra-low voltage SELV).
SIMATIC VS 130 does not have integrated protection against surge in
the µs range. For external measures, see EMC.
Yes
≥ 20 ms
typically: I = 2 A (maximum load of 1.5 A over the digital inputs/outputs)
max. 10 A
max. 10 A; < 1 ms
1
IEC 61131-2 corresponds to DIN EN 61131-2
Test voltage
±8 kV
Discharge in air:
Contact discharge: ±6 kV
2 kV (power supply cable)
2 kV (signal line)
Test voltage
2 kV (power supply cable) direct voltage with protective
elements
1 kV (power supply cable) direct voltage with protective
elements
Test values
10 V/m at 80 % amplitude modulation of 1 kHz in the
range from 80 MHz to 1000 MHz
10 V/m at 50 % pulse modulation at 900 MHz
Test values
Test voltage 10 V at 80 % amplitude modulation of
1 kHz in the range from 9 kHz to 80 MHz
Appendix
Corr. to
severity
3
3
Corr. to
severity
3
3
Corr. to
severity
3
3
Corr. to
severity
3
A-5

Advertisement

Table of Contents