Putting into Operation
4.2

Adjusting the Sensor with the Setup Software

Before you start to work with the SIMATIC VS 130, you must first align the sensor
head correctly using the setup software on a PG / PC. The setup software shows
you an image as seen by the sensor head. For more detailed information on the
setup software, refer to Appendix A.7.
Step
Activity
1
Starting the setup software on the PC / PG
1.
Turn on the PG /PC and wait until the computer has booted.
2.
Turn on the processing unit.
3.
Connect the two devices over a serial cable.
4.
Insert the CD with the setup software "ADJUST-SW". The program starts automatically.
5.
If the program does not start automatically, you can start it manually by selecting the CD
drive and double-clicking on ADJUST-SW.
6.
Turn the processing unit to "Adjust".
Result:
Once the setup software has started, the sensor field of view is displayed on the PC/PG
monitor. The displayed image is updated several times per second.
2
Adjusting the Sensor
1.
Bring the data matrix code into the image.
2.
Set a sharp image by adjusting the distance between the end of the sensor head and the
data matrix code correctly.
3.
Correct the shutter speed and the brightness if necessary.
4.
Minimize reflection.
5.
Activate the "Triggered only" check box to test the trigger signal.
6.
Activate the "Read" check box to check whether the code can be read, and make any
necessary fine adjustments.
Note:
If you have too many errors, clean the lens and diffuser with a lint-free cloth.