Siemens SIMATIC VS130 Series Manual page 71

Vision sensor
Table of Contents

Advertisement

Mechanical Environmental Conditions for Operation
Test for / Test standard
Shock
Shock test
complying with
IEC 60068-2-29
Shock test
complying with
IEC 60068-2-27
Climatic Environmental Conditions for Operation
Environmental Conditions Permitted Range
Temperature
Temperature change
Relative humidity
Air pressure
Contaminant concentration
Note
The mechanic and climatic ambient conditions specified above for operation are
valid for only sensor heads with order numbers 6GF2 002-8DA and
6GF2 002-8EA.
The mechanic and climatic ambient conditions for the sensor head with order
number 6GF2 002-8CA depend on the lens used.
Test voltages to IEC 61131-2
Circuits with rated voltage U
≤ 50 V
0 V < U
e
≤ 100 V
50 V < U
e
≤ 150 V
100 V < U
e
≤ 300 V
150 V < U
e
Vision Sensor VS 130
A5E00199459-01
Remarks
Type of shock: half sine
Strength of the shock:
Processing unit: 10 g peak value / 16 ms duration
-
Sensor head, illumination: 10 g peak value / 16 ms duration
-
Direction of shock: 100 shocks in each of the 3 perpendicular axes
Sensor head, illumination:
70 g peak value / 6 ms duration 3 times in each direction
30 g peak value / 11 ms duration 3 times in each direction
0 to +50 °C
Max. 10 °C/h
Max. 95 % at +25 °C
1080 to 795 hPa (corresponds to a height of
-1000 to 2000 m)
SO
: < 0.5 ppm;
2
RH < 60 %, no condensation
H
S: < 0.1 ppm;
2
RH < 60 %, no condensation
to other circuits or ground
e
Appendix
Note
No condensation,
corresponds to
relative humidity
degree 2 to
IEC 61131-2
Test: 10 ppm;
4 days
Test: 1 ppm;
4 days
Test voltage
350 V
700 V
1300 V
2200 V
A-7