Diagnostics
Cons.
Message
Bit No.
No.
Starting at
Diagnostic
Byte 0 (DP)
13
Error
10
Training
Code
14
Error Match
11
Mismatch
15
Error
12
No ECC200
Code
7-4
Description
The code was not legible
and could not be saved.
You are attempting to train
a code that does not match
the settings made in
Settings>Match.
You are attempting to train
a code that does not comply
with the ECC200 standard
or is base256 coded.
Other possible error: The
code you are reading has
print errors so that the code
cannot be identified as
ECC200 code (without
base256).
Possible Remedies
Check the following potential source of
error and make corrections as
necessary:
There was no code in the sensor
field of view.
The code was not completely in
the sensor field of view.
The code was too close to the
edge of the field of view (2 dots
minimum clearance are
necessary).
The dot size is too small.
The dot size is too large.
The image is too bright or too
dark, the code visible to the sensor
is damaged.
The code is damaged or defective.
It is a die-punched code.
The viewing angle to the code is
too steep. The permitted angle is
between 0 and 45 degrees to the
vertical.
The dot type is not correctly
configured
Check the values in Settings>Match
and make sure that these are valid for
the code you want to read.
Example: There must be a specified ID
in the data matrix code.
Use a data matrix coding conforming
with ECC200. (Base256 of the
ECC200 standard is also not
supported).
Vision Sensor VS 130
A5E00199459-01